saturated steam at 5 bar boiler

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :saturated steam at 5 bar boiler
  • Supply Capacity : 10 units/month :saturated steam at 5 bar boiler
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • SATURATED STEAM TABLES - Byworth Boilers

    to calculate the actual steam produced by a 5000 kg/hr steam boiler operating at 7 bar with feed water supplied at 85°C M 5000 kg/hr = 4677 kg/hr Ahg 2769.1 kJ/kg (from the table overleaf) 2769.1 - (85 x 4.19) TF 85 °C To calculate the required blowdown rate of a boiler Blowdown rate = F x S Where; B - F F Feed tank TDS in ppmGet Price

  • Steam Turbines: Basics, Types, Selection, Components

    Process 2–3 Constant pressure heat addition in a boiler – Isobaric Heat Supply: The high-pressure liquid enters a boiler, where it is heated at constant pressure by an external heat source to become a dry saturated vapour (steam). The required energy input can easily be calculated graphically, using an enthalpy–entropy chart (Mollier Get Price

  • Natural Steam Methane Reforming (SMR)

    Treated gas 10 - 15°F increase, 5 - 10 psi decrease, water saturated Treated gas 100°F & 230 psi (16 bar) exit Rejected CO2 atmospheric pressure & water saturated 95% CO2 recovery Steam Boiler 3,742,371 Post Reformer Cooler 2,238,933 Reformer 6,332,965 Post HTS Cooler 1,026,525Get Price

  • Pressurised Deaerators | Spirax Sarco

    Boiler:-Operating pressure (P1) = 10 bar g-'From and At' rating = 10 000 kg/h-Actual output = 9 311 kg/h with a feedwater temperature of 85°C Deaerator:-Operating pressure (P2) = 0.2 bar g (Saturation temperature 105°C) The steam control valve Sizing a control valve for saturated steam service can be determined using Equation 3.21.2Get Price

  • Boiler Efficiency - an overview | ScienceDirect Topics

    Superheater, drums, and boiler tube system maximum design pressure, the vendor to specify, but a minimum of 300 kPa (3 bar) above operating pressure is required. • Steam drum and boiler tube system maximum design temperature specified on data sheet, superheater design temperature per …Get Price

  • Compre Special Project (PPE &IPE) | PDF | Boiler | Thermal

    Steam, initially saturated at 2.05 MPa, passes through a 10.10 cm standard steel pipe for a total distance of 152 m. The steam line is insulated with 5.08 cm thickness of 85% magnesia. For an ambient temperature of 22C, what is the quality of the steam which arises at its destination if the mass flow rate is 0.125 kg steam per second?Get Price

  • Steam Accumulators | Spirax Sarco

    In Figure 3.22.14, the boiler is steaming at its normal design pressure, for example 10 bar, and the steam passes to variable loads which require not more than, for example 5 bar. Pressure reducing valve A is reducing pressure between the boiler header and the distribution main in the plant, responding to the pressure sensed in the 5 bar line.Get Price

  • This Experiment Marcet Boiler Engineering Essay

    Dec 28, 2016 · The Marcet boiler is used to investigate the between pressure and temperature of saturated steam, in equilibrium with water, at all pressures between atmospheric and a 14bar An ideal gas can be characterized by three state variables: absolute pressure (P), volume (V), and absolute temperature (T).Get Price

  • SATURATED STEAM TABLES - Byworth Boilers

    to calculate the actual steam produced by a 5000 kg/hr steam boiler operating at 7 bar with feed water supplied at 85°C M 5000 kg/hr = 4677 kg/hr Ahg 2769.1 kJ/kg (from the table overleaf) 2769.1 - (85 x 4.19) TF 85 °C To calculate the required blowdown rate of a boiler Blowdown rate = F x S Where; B - F F Feed tank TDS in ppmGet Price

  • House Renovation Costs For 2022 | Estimate Remodeling Costs

    Dec 27, 2021 · Includes boiler, radiators/baseboards and new gas boiler. Oil boiler + new oil tank will be about $1700 extra. See the differences between Oil vs Gas boiler. Electric Sub-Floor Heating Installation: $15,000-18,000 or $10-12/sq.ft: This cost estimate is for a 1,500 sq.ft. space and includes all labor and materials.Get Price

  • Water-tube boiler - Wikipedia

    A high pressure watertube boiler (also spelled water-tube and water tube) is a type of boiler in which water circulates in tubes heated externally by the fire. Fuel is burned inside the furnace, creating hot gas which boils water in the steam-generating tubes.In smaller boilers, additional generating tubes are separate in the furnace, while larger utility boilers rely on the water-filled …Get Price

  • Steam and Condensate - What is Steam and the properties of

    Steam produced in any shell-type boiler, where the heat is supplied only to the water and where the steam remains in contact with the water surface, may typically contain around 5% water by mass. If the water content of the steam is 5‰ by mass, then the steam is said to be 95% dry and has a dryness fraction of 0.95.Get Price

  • Boiler - Wikipedia

    Fire-tube boiler Here, water partially fills a boiler barrel with a small volume left above to accommodate the steam (steam space).This is the type of boiler used in nearly all steam locomotives.The heat source is inside a furnace or firebox that has to be kept permanently surrounded by the water in order to maintain the temperature of the heating surface below the …Get Price

  • Steam and Condensate - What is Steam and the properties of

    Steam produced in any shell-type boiler, where the heat is supplied only to the water and where the steam remains in contact with the water surface, may typically contain around 5% water by mass. If the water content of the steam is 5‰ by mass, then the steam is said to be 95% dry and has a dryness fraction of 0.95.Get Price

  • Pressurised Deaerators | Spirax Sarco

    Boiler:-Operating pressure (P1) = 10 bar g-'From and At' rating = 10 000 kg/h-Actual output = 9 311 kg/h with a feedwater temperature of 85°C Deaerator:-Operating pressure (P2) = 0.2 bar g (Saturation temperature 105°C) The steam control valve Sizing a control valve for saturated steam service can be determined using Equation 3.21.2Get Price

  • Boiler Efficiency - an overview | ScienceDirect Topics

    Superheater, drums, and boiler tube system maximum design pressure, the vendor to specify, but a minimum of 300 kPa (3 bar) above operating pressure is required. • Steam drum and boiler tube system maximum design temperature specified on data sheet, superheater design temperature per …Get Price

  • Boiler Mountings & Accessories - Basics, Types, Working

    A steam boiler is a closed vessel that generates steam by applying heat energy to water. A bourdon tube type pressure gauge is used. The gauge is graduated in units of Bar, one end of which is closed, and the other is connected to the steam space using siphon (U-tube). Saturated steam obtained from all types of boilers contains some Get Price

  • This Experiment Marcet Boiler Engineering Essay

    Dec 28, 2016 · The Marcet boiler is used to investigate the between pressure and temperature of saturated steam, in equilibrium with water, at all pressures between atmospheric and a 14bar An ideal gas can be characterized by three state variables: absolute pressure (P), volume (V), and absolute temperature (T).Get Price

  • 3. STEAM SYSTEM

    Figure 3.1 Steam Phase Diagram For a boiler is operating at a pressure of 8 kg/cm2, steam saturation temperature is 170 oC, and steam enthalpy or total heat of dry saturated steam is given by: h f +h fg = 171.35 +489.46 = 660.81 kCal/kg. If the same steam contains 4% moisture, the total heat of steam is given by: 171.35+ 0.96 x 489.46 = 641.23 Get Price

  • Indeck Power Equipment Company | Engineered Solutions

    The Indeck Group is a single source supplier of boiler systems and we are one of the top manufacturers of industrial steam boilers in the U.S. We offer custom boiler systems and industrial steam boilers for sale and for rent. For steam boiler rental, call us at 847-541-8300 or review our full product line below.Get Price

  • 3. STEAM SYSTEM

    Figure 3.1 Steam Phase Diagram For a boiler is operating at a pressure of 8 kg/cm2, steam saturation temperature is 170 oC, and steam enthalpy or total heat of dry saturated steam is given by: h f +h fg = 171.35 +489.46 = 660.81 kCal/kg. If the same steam contains 4% moisture, the total heat of steam is given by: 171.35+ 0.96 x 489.46 = 641.23 Get Price

  • Rankine Cycle - an overview | ScienceDirect Topics

    The high-pressure liquid enters a boiler, where it is heated at constant pressure to the compressed liquid (Step 2-3) and two-phase (i.e., water and steam) mixture (Step 3-4). The steam is then passed through the superheaters, where it superheated (Step 4-5). The steam is then expanded through a turbine to generate power (Step 5-6).Get Price

  • Profitec Pro 300 Dual Boiler Espresso Machine – Clive Coffee

    The Profitec Pro 300 is a German-designed dual boiler, saturated group head, reservoir-only espresso machine with a vibratory pump and a built-in PID and shot timer. Who is it for? The espresso beginner who wants all the best tools for espresso and milk drinks at their disposal, but in a footprint that fits in their kitchen, in a minimalist Get Price

  • Steam Accumulators | Spirax Sarco

    In Figure 3.22.14, the boiler is steaming at its normal design pressure, for example 10 bar, and the steam passes to variable loads which require not more than, for example 5 bar. Pressure reducing valve A is reducing pressure between the boiler header and the distribution main in the plant, responding to the pressure sensed in the 5 bar line.Get Price

  • Boiler Mountings & Accessories - Basics, Types, Working

    A steam boiler is a closed vessel that generates steam by applying heat energy to water. A bourdon tube type pressure gauge is used. The gauge is graduated in units of Bar, one end of which is closed, and the other is connected to the steam space using siphon (U-tube). Saturated steam obtained from all types of boilers contains some Get Price

  • Boiler – Fundamentals and Best Practices

    Steam Production From steam tables we can see that the total heat of steam does not vary a great deal as the boiler pressure increase The boiling point (b.p.) increases as the pressure increases Thus the sensible heat increases as the pressure increases, and the latent heat decreases Boiler pressures are expressed in psia, psig, bar, kg/cm2 Get Price

  • Boiler – Fundamentals and Best Practices

    Steam Production From steam tables we can see that the total heat of steam does not vary a great deal as the boiler pressure increase The boiling point (b.p.) increases as the pressure increases Thus the sensible heat increases as the pressure increases, and the latent heat decreases Boiler pressures are expressed in psia, psig, bar, kg/cm2 Get Price

  • Boiler - Wikipedia

    Fire-tube boiler Here, water partially fills a boiler barrel with a small volume left above to accommodate the steam (steam space).This is the type of boiler used in nearly all steam locomotives.The heat source is inside a furnace or firebox that has to be kept permanently surrounded by the water in order to maintain the temperature of the heating surface below the …Get Price

  • Package Boilers, Watertube Boilers, Utility Boilers - John

    Steam Output. Steam output from the Torripac boiler range is from 1 000 kg/h to 13 000 kg/h. Design pressures of up to 32 bar are available to be used in conjunction with saturated steam screw expanders for cogeneration applications. For higher power outputs, superheaters can be incorporated into the design for use with steam turbines.Get Price

  • Water-tube boiler - Wikipedia

    A high pressure watertube boiler (also spelled water-tube and water tube) is a type of boiler in which water circulates in tubes heated externally by the fire. Fuel is burned inside the furnace, creating hot gas which boils water in the steam-generating tubes.In smaller boilers, additional generating tubes are separate in the furnace, while larger utility boilers rely on the water-filled …Get Price

Discount
7X24 Online